Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
5.
Cell Biochem Funct ; 41(8): 953-958, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37653690

RESUMO

The impact of bilirubin levels on wound healing remains a topic of controversy. The present study is a literature review that examines the impact of increased levels of bilirubin in the bloodstream on the process of wound healing. The physiological pathways and their interrelationships, as well as the relevant research publications, were comprehensively addressed in our discussion. The present study undertook a comprehensive review of the extant literature pertaining to the impact of bilirubin concentration on the process of wound healing, with particular emphasis on its association with reactive oxygen species. This scholarly article provides an overview of several studies that elucidate the mechanisms and correlation between bilirubin and the process of wound healing. The impact of bilirubin on wound healing has been observed, and it appears to function as a modulator. This review demonstrates that there exists a spectrum of bilirubin concentrations that can function as precise regulators, although this range falls under pathological hyperbilirubinemia. Further research is required to determine the precise boundary of this range. Within a certain range, bilirubin serves as a positive regulator in the process of wound healing. Beyond this range, it has the potential to function as a negative regulator.


Assuntos
Bilirrubina , Cicatrização , Espécies Reativas de Oxigênio/metabolismo
8.
Indian J Crit Care Med ; 27(4): 297, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37378035

RESUMO

How to cite this article: Choudhary N, Magoon R, Jose J. Deliberating a Re(n)al-world Research Setting. Indian J Crit Care Med 2023;27(4):297.

9.
11.
Indian J Anaesth ; 66(6): 456-459, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35903587

RESUMO

Safe paediatric sedation in a magnetic resonance imaging (MRI) suite can be challenging. The challenges intensify in uncooperative syndromic children compounded by an accentuated risk of periprocedural cardio-respiratory complications with anaesthetic sedation in this peculiarly predisposed subset. Amidst ardent debates on the ideal sedative agent for paediatric MRI, we report an encouraging application of ketamine-dexmedetomidine combination (ketodex) sedation for MRI in our case-series including syndromic children with coexistent congenital cardiac anomalies.

12.
Indian J Crit Care Med ; 26(2): 164-166, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35712729

RESUMO

Coronavirus disease-2019 (COVID-19) and the associated pathophysiological perturbations continue to bewilder the fraternity at large. In this context, the thromboembolic predisposition in COVID-19 has particularly emerged as a matter of an ardent debate. The index commentary aims to present an account of the recent developments in the understanding of the immunothrombosis in the enigmatical setting of COVID-19. How to cite this article: Magoon R, Choudhary N, Jose J. Fibrinolysis and D-dimer in COVID-19: A Twisted Plot! Indian J Crit Care Med 2022;26(2):164-166.

13.
ACS Appl Mater Interfaces ; 14(25): 29014-29024, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35700345

RESUMO

Aluminum nitride (AlN) continues to kindle considerable interest in various microelectromechanical system (MEMS)-related fields because of its superior optical, mechanical, thermal, and piezoelectric properties. In this study, we use magnetron sputtering to tailor intrinsic stress in AlN thin films from highly compressive (-1200 MPa) to highly tensile (+700 MPa), with a differential stress of 1900 MPa. By monolithically combining the compressive and tensile ultrathin AlN bilayer membranes (20-60 nm) during deposition, perfectly curved three-dimensional (3D) architectures are spontaneously formed upon dry-releasing from the substrate via a 3D MEMS approach: the complementary metal-oxide-semiconductor (CMOS)-compatible strain-induced self-rolled-up membrane (S-RuM) method. The thermal stability of the AlN 3D architectures is examined, and the curvature of S-RuM microtubes and helical structures as a function of the cumulative membrane thickness and stress are characterized experimentally and simulated using a finite-element physiomechanic method. By combining AlN with various materials such as metal (Cu) and silicon nitride (SiNx), AlN-based hybrid S-RuM microtubes with diameters as small as ∼6 µm are demonstrated with a near-unity yield (∼99%). Compared with other stressed thin films for S-RuMs, including PECVD SiNx, magnetron-sputtered AlN-based S-RuMs show better structural controllability and versatility, probably due to the high Young's modulus and stress uniformity. This work establishes the sputtered AlN thin film as a superior stress-configurable S-RuM shell material for high-performance applications in miniaturizing and integrating electronic components beyond those based on other materials such as SiNx. In addition, for the first time, a single-crystal Al1-xScxN/AlN bilayer grown by molecular beam epitaxy is successfully rolled-up with the diameter varying from ∼9 to 14 µm, paving the way for 3D tubular Al1-xScxN piezoelectric devices.

14.
J Anaesthesiol Clin Pharmacol ; 37(2): 255-260, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34349376

RESUMO

BACKGROUND AND AIMS: Laparoscopic cholecystectomy is one of the commonly performed ambulatory surgeries. The selection of anesthetic agents for ambulatory surgeries should be done bearing in mind the need for early discharge. Opioids form an integral component of total intravenous anesthesia (TIVA) but their associated side effects may result in an increased hospital stay. Hence, we planned a study to compare the opioid (fentanyl) and non-opioid (dexmedetomidine) based technique of TIVA for laparoscopic surgery. MATERIAL AND METHODS: Ninety ASA I and II patients between 18-60 years of either sex posted for laparoscopic cholecystectomy were randomly allocated into two groups namely group D (Dexmedetomidine) and group F (Fentanyl). Patients received propofol infusion along with group specific drug infusion, after which an appropriate size proseal laryngeal mask airway was placed. The patients were assessed for discharge time from post-anesthesia care unit (PACU), on table recovery time, time to first rescue analgesia, hemodynamic parameters, incidence of postoperative nausea and vomiting (PONV) and any other complication. RESULTS: Demographic profile of both the groups was comparable. Group D had longer on table recovery time (13.00 ± 2.34 min vs 6.29 ± 2.46 min; P < 0.001) and time to discharge from PACU (6.80 ± 3.96 min vs 2.36 ± 1.67 min; P < 0.001) compared to group F. Group F had better hemodynamic stability compared to group D. In group D, 77% patients required rescue analgesia in first one hour post surgery, unlike 22% in group F. No patient in group D had PONV. CONCLUSION: Opioid based technique (Fentanyl) of TIVA is superior over non-opioid based (dexmedetomidine) technique with faster recovery, early discharge, decreased postoperative pain scores and better hemodynamic stability. PONV is observed with opioids which can be treated successfully with antiemetics.

15.
Saudi J Anaesth ; 15(2): 219-221, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34188647

RESUMO

As the motivation to potentially allow for a more expansive role of opioid-sparing anaesthesia in various surgical specialities transpire with new zeal, promising evidence needs to be accumulated to substantiate the same. Appropriate to this context, the index case series highlight the beneficial effects of an intraoperative magnesium sulphate infusion on perioperative hemodynamic profile and postoperative recovery in patients undergoing intracranial cerebral aneurysm surgery.

18.
J Family Med Prim Care ; 9(6): 3010-3014, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32984164

RESUMO

BACKGROUND AND AIMS: Poisoning is most common method of committing suicide in India. Objectives of this study to assess prevalence of suicidal poisoning among all poisoning cases, its socio-demographic profile and its reasons in all admitted cases of suicidal poisoning in hospital. METHODS: A cross-sectional study was conducted on cases of poisoning of any age group admitted in the Chhatrapati Shivaji Subharti Hospital, Meerut. Poisoning cases with history or evidence of suicide were further interviewed. A semi-structured interview schedule in Hindi was used to collect data. Microsoft Excel 365 and R software version 3.6.0 were used for data entry and analysis respectively. RESULTS: Among total 135 poisoning cases admitted in hospital, 126 provided consent and included in the study. Prevalence of suicidal poisoning was 77.7% (98). Most common age group involved was 11-20 years (36.7%) and 21-30 years (35.7%) and most of the participants were males (59.2%). Most suicidal poisoning cases took Aluminum Phosphide (31.6%), followed by Organophosphates (20.4%) as poison. Most frequent reasons for suicide as described by participants were 'Family quarrel or family unhappiness' (29.6%), 'failure in examination or interview or business' (23.5%), 'ill treatment by spouse or in laws' (16.3%) and 'unemployment' (9.2%). CONCLUSION: Our study shows that consuming Agriculture poisons (Aluminum Phosphide and Organophosphates) are most common (52%) poisons consumed by suicidal poisoning cases. Agriculture poisons (Aluminum Phosphide and Organophosphates) are easily available in markets in India. There should be some restriction on their purchase to reduce suicidal incidences.

19.
Indian J Crit Care Med ; 24(6): 473-474, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32863642

RESUMO

How to cite this article: Choudhary N, Magoon R, Walian A, Kohli JK. Pulmonary Vascular Permeability Indices: Fine Prints of Lung Protection? Indian J Crit Care Med 2020;24(6):473-474.

20.
Nanotechnology ; 31(43): 435405, 2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-32629437

RESUMO

Flexible smart electronics require their energy storage device to be flexible in nature. Developing high-performance flexible energy storage devices require direct integration of electrode active materials on current collectors to satisfy the high electronic/ionic conductivity and long-term durability requirements. Herein, we develop a flexible all-solid-state asymmetric supercapacitor comprised of reduced graphene oxide (rGO) and core/shell tungsten trioxide/tungsten disulfide (WO3/WS2) nanowire based electrodes. The electrodes synthesized via electrochemical deposition and chemical vapor deposition avoided the necessity to use non-conductive binders and offered excellent cyclic stability. The structural integrity provided by the rGO and WO3/WS2 electrodes facilitated excellent electrochemical stability with capacitance retention of 90% and 100% after 10 000 charge-discharge cycles, respectively. An all-solid-state device provides a voltage window of 1.5 V and more than 70% capacitance retention after 10 000 charge-discharge cycles. Providing 97% capacitance retention upon mechanical bending reveals its potential to be used as an energy storage devices in flexible electronics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...